In the highly alkaline environment of concrete, carbon steel rebar is protected against corrosion by a passive oxide/oxyhydroxide film. Understanding the characteristics of this passive film, and how it depassivates, is the key for mitigating problems associated with steel corrosion in concrete. Although a large number of electrochemical and analytical...
The collapse of the I-35W Bridge in Minneapolis, MN on August 1, 2007 brought into question the design and inspection of gusset plates in steel truss bridges. The experimental tests performed in this research study the sway-buckling strength and behavior of large-scale steel gusset plates in an isolated truss connection....