New delivery methods for radiotracers are constantly being proposed. Two key properties of the delivery method must be analyzed: dose to patient and effectiveness of delivery. In this work, the localized skin dose for intranasal administration of 18F was determined utilizing MCNP code. An anatomically accurate nasal cavity was constructed...
Current neutron dosimetry methods rely on the assumption that charged particle equilibrium (CPE) is established within the tissue medium. This maintains that the kinetic energy transferred to the medium (KERMA) is equivalent to absorbed dose. However, this assumption is only valid for large volumes such as the whole body. For...
The lens dose equivalent (LDE) is a regulatory limit set to protect radiation workers. Current methods for estimating the LDE are specific to beam sources in a vacuum and require interpolating data from tables. A new set of deterministic equations for photon and electron point sources has been developed. These...
Since the International Commission on Radiation Protection (ICRP) recommended a revision to the eye lens dose limits in ICRP Publication 118 (Stewart, 2012) the radiation protection community has conducted many new studies related to eye dosimetry. The recommended reduction of eye lens dose limits may result in the reduction of...
:
______________________________________________________________
DavidM. Hamby
Abstract:
Since the International Commission on Radiation Protection (ICRP
When the ICRP updated their recommended limits for eye dose, they ignited a renewed interest in eye dosimetry. Especially, how the updated eye dose estimates affect current regulations and what that would mean to a radiation worker. Radiation workers are commonly required to wear leaded eyeglasses to reduce their dose...
:
_____________________________________________________________________________________
DavidM. Hamby
Abstract:
When the ICRP updated their recommended limits for eye dose, they
Internal dosimetry models show a representation of how radionuclides move through the body. This study takes a look at radiation wounds by modelling a puncture wound to the hand using Microshield software. An analysis of these models provides a triangulation method that could be used to investigate wound characteristics, as...
Cancer risk at low-dose ionizing radiation has been the subject of great scientific controversy in the past century. The clear majority of national and international radiation protection regulators adopt the linear no-threshold (LNT) model based on the atomic-bomb survivors Life Span Study (LSS) for solid cancer risk assessment. The LNT...
Nuclear energy is very efficient and cost-effective, but the stigma attached to it hinders its expansion around the world. However, with rising concerns over climate change and the fact that nuclear energy effectively has zero greenhouse gas emissions, there is an opportunity for nuclear to be more acceptable as a...
CR-39 foils were irradiated as part of nuclear accident dosimetry experiments using the Godiva reactor at the Nevada National Security Site and the Caliban and Prospero reactors at the Valduc Centre for Nuclear Studies in France. The irradiated foils were chemically etched using the standard Lawrence Livermore National Laboratory process...