Efficient use of water in agricultural production involves accurate assessment
and control of the quantity and spatial uniformity of excess percolation. Passive
Capillary Samplers (PCAPS), which sample water from the vadose zone have shown
potential to provide superior estimates of soil water flux compared to alternative
methods. In a four-year...
A method is described for determining the partition coefficient, K, for radon gas
distributed between an aqueous phase and an organic solvent. The method uses
sequential extractions of radon into equal volume aliquots of organic solvent. The
radon-laden organic liquid is then counted on a liquid scintillation analyzer with alpha-beta...
At Site-300, Lawrence Livermore National Laboratory (LLNL), CA,
trichloroethene (TCE) is present along with tetraalkoxysilanes such as tetrabutoxysilane
(TBOS) and tetrakis(2-ethylbutoxy) silane (TKEBS), as subsurface contaminants.
Intrinsic transformation of TCE to cis-dichloroethene (c-DCE) was observed in the
groundwater at locations co-contaminated with TBOS or TKEBS. Attenuation of TBOS
and TKEBS...