This study investigates the applicability of the database-assisted design (DAD) methodology to predict structural reactions in a light-framed wood structure subjected to fluctuating wind pressures. Structural influence functions were determined on a 1/3-scale light-frame wood structure, which was then subjected to a wind flow, while the surface pressures and structural...
The assessment of losses during extreme events such as hurricanes is important for performance-based design of residential buildings. In this paper, a methodology for estimating the probability of debris impact, specifically roof sheathing panels, to windows as a result of hurricanes is introduced and applied to a series of illustrative...
In the summer of 2009, a full-scale midrise wood-frame building was tested under a series of simulated earthquakes on the world’s largest shake table in Miki City, Japan. The objective of this series of tests was to validate a performance-based seismic design approach by qualitatively and quantitatively examining the building’s...
Tornadoes represent a unique natural hazard because of the very low probability of occurrence, short warning times (on the order of only a few minutes), and the intense and destructive forces imposed on engineered and nonengineered buildings. The very low-probability/very high-consequence nature of a tornado strike makes designing for survival...
Global sustainability goals have led to the development of the green building movement. The Green Building Program, stemming from the movement, has had unprecedented success as it provides a quantifiable metric to people’s efforts towards sustainable development. Sustainable development and green buildings are often used interchangeably. Although, sustainable development and...
The objective of this project was to evaluate system effects and further define load paths within a light-frame wood structure under extreme wind events. The three-dimensional 30- by 40-ft (9.1- by 12.2-m) building, designed to be representative of typical light-frame wood construction in the southeastern coastal region of the United...
The overall goal of this project was to design a wood frame shear wall that could withstand greater displacement before damage occurred to the gypsum wall board (GWB). A total of 14 shear walls consisting of seven different designs with two walls built per design were tested to failure. Six...
Current compression perpendicular-to-grain (C⊥) design values for wood members are based on mean stress obtained from ASTM D143 specimen. The standard ASTM test with metal on wood bearing has limited applicability in modern construction assemblies with C⊥ loading scenarios. Previous work has shown that end-bearing conditions and wood-on-wood C⊥ bearing...
Compression perpendicular to grain (C┴) of wood is an important property and has a drastic effect on serviceability of the structure. Typical C┴ loading scenarios include the bottom chord of a truss resting on the top plate of a shear wall and chords of a shear wall resting on the...
For wood beams, it is often assumed that the neutral axis (NA) is located at the centroid of the beam. This would be the case for isotropic and homogeneous materials but these prerequisites are not valid for wood. The varying grain patterns and knots located throughout wood make wood anisotropic...