Current compression perpendicular-to-grain (C⊥) design values for wood members are based on mean stress obtained from ASTM D143 specimen. The standard ASTM test with metal on wood bearing has limited applicability in modern construction assemblies with C⊥ loading scenarios. Previous work has shown that end-bearing conditions and wood-on-wood C⊥ bearing...
Compression perpendicular to grain (C┴) of wood is an important property and has a drastic effect on serviceability of the structure. Typical C┴ loading scenarios include the bottom chord of a truss resting on the top plate of a shear wall and chords of a shear wall resting on the...
Current compression perpendicular-to-grain (C-perpendicular to) design values for wood members are based on mean stress obtained from ASTM D143 specimen. The standard ASTM test with metal on wood bearing has limited applicability in modern construction assemblies with C-perpendicular to loading scenarios. Previous work has shown that end-bearing conditions and wood-on-wood...