For wood beams, it is often assumed that the neutral axis is located at the centroid of the
beam. The neutral axis of isotropic, homogeneous materials is located at the centroid of the
material, but wood is neither isotropic nor homogeneous. The varying grain patterns and
knots located throughout wood...
In a homogenous and isotropic material, the location of the neutral axis coincides with the location of the centroid of the beam. Wood is anisotropic, meaning that it has different properties in different directions. It is also non-homogenous, meaning that the beam exhibits different properties at different locations throughout its...
The objective of this project was to develop an analytical model of a light-framed wood structure using a prevalent structural analysis computer program in order to evaluate system effects and define load paths within the structure, especially under extreme wind events. Simplified modeling techniques and material definitions were developed and...
The overall goal of this project was to design a wood frame shear wall that could withstand greater displacement before damage occurred to the Gypsum Wall Board (GWB). More specifically, the objectives of the study were: (1) to evaluate damage to the GWB in alternative shear wall designs at 1%,...
The objective of this study was to investigate load paths in an existing light-frame wood structure with complex geometry, using previously established computer modeling methods. The structural model is derived from an existing, multi-level residence located in Corvallis, Oregon. For the purpose of this study, the existing structure was simplified...
The objective of this project was to evaluate methods to remediate a wood I-joist with a single, circular hole in the web while leaving utilities in place. The methods were experimentally evaluated with a full-scale bending test using four equally spaced point loads. There were three depths of joists with...
The goal of this project is to contribute to the development of design values for cross-laminated timber (CLT) diaphragms in the seismic load-resisting system for buildings. Monotonic and cyclic tests to determine strength and stiffness characteristics of 2.44 m (8 ft) long shear connections with common self-tapping screws were performed....
The objectives of this study are to use SAP2000 to investigate lateral load paths and system behavior in a modular, light-frame wood structure by investigating different foundation configurations and to further develop and validate existing modeling techniques of shear wall elements based on the Perforated Shear Wall Method. The modeling...
Since 2004 there have been multiple devastating tsunamis around the globe triggered by large magnitude earthquakes; with the most recent being the Tohoku, Japan tsunami in March 2011. These tsunamis have caused significant loss of life and damage to the coastal communities impacted by these powerful waves. The resulting devastation...
Engineers, in practice, are often faced with the challenge of evaluating a fire-damaged structure and developing a rehabilitation and retrofit plan. In order to decide on a rehabilitation and retrofit plan, information on thermal degradation of building materials and connections are vital. A critical knowledge gap exists in terms of...