Ammonium chloride aerosols of submicron size generated by
condensation and dispersion methods were treated, shortly after aerosol
charging, with shock waves originating from diaphragm pressure
ratios of up to 5.75.
The fraction of the particulate matter remaining in suspension
after a given time was measured as an indication of coagulation...