To quantify the postpeak residual capacity and
to gain insights into the load transfer mechanism of a shear
wall, nail connection tests were performed on salvaged
connections after a monotonic shear wall test loaded up
to peak load. Experimental results reveal that there is a
loss of strength in most...
The effect of grain angle (GA) on shear strength of Douglas-fir has been evaluated. Shear block specimens with a GA varying from 0 to 90° was loaded in the shear plane, resulting in failure mode transitioning from parallel to grain shear to rolling shear. As expected, shear strength decreased as...
The effect of grain angle (GA) on shear strength of Douglas-fir has been evaluated. Shear block specimens with a GA varying from 0 to 90° was loaded in the shear plane, resulting in failure mode transitioning from parallel to grain shear to rolling shear. As expected, shear strength decreased as...
This study investigated the effect of exposure to elevated temperature on the yield strength of single-shear nail connections when subjected to lateral loading. Solid sawn lumber and laminated veneer lumber were used as framing members and two different thicknesses of both oriented strand board and plywood were used as the...
Wood and wood-based composites are being used extensively in single-family residential dwellings. Therefore, it is important to categorize their response when exposed to elevated temperatures for a sustained period of time. In fire-resistant design for wood structures, the main goal is to ensure that enough structural integrity is maintained, during...
Wood and wood-based composites are being used extensively in single-family residential dwellings. Therefore, it is important to categorize their response when exposed to elevated temperatures for a sustained period of time. In fire-resistant design for wood structures, the main goal is to ensure that enough structural integrity is maintained, during...
For wood beams, it is often assumed that the neutral axis (NA) is located at the centroid of the beam. This would be the case for isotropic and homogeneous materials but these prerequisites are not valid for wood. The varying grain patterns and knots located throughout wood make wood anisotropic...
For wood beams, it is often assumed that the neutral axis (NA) is located at the centroid of the beam. This would be the case for isotropic and homogeneous materials but these prerequisites are not valid for wood. The varying grain patterns and knots located throughout wood make wood anisotropic...
Global sustainability goals have led to the development of the green building movement. The Green Building Program, stemming from the movement, has had unprecedented success as it provides a quantifiable metric to people’s efforts towards sustainable development. Sustainable development and green buildings are often used interchangeably. Although, sustainable development and...
Global sustainability goals have led to the development of the green building movement. The Green
Building Program, stemming from the movement, has had unprecedented success as it provides a quantifi able
metric to people’s efforts towards sustainable development. Sustainable development and green buildings are often
used interchangeably. Although, sustainable development...