'Hot particle' skin dosimetry calculations are commonly performed using homogeneous dose-point kernels (DPK) in conjunction with scaling and backscatter models to account for non-homogeneous geometries. A new scaling model for determining the actual DPK for beta-particles transmitted by a high-Z source material has been developed. The model is based on...
As human exploration of space continues, eventually sights will be set on establishing a permanent manned habitat on the surface of Mars. The success of such a base will depend on many new and developing technologies. Low mass and high energy density power production units will be of paramount importance....
The human health and environmental effects following a postulated accidental release of radioactive material to the environment has been a public and regulatory concern since the early development of nuclear technology and researched extensively to better understand the potential risks for accident mitigation and emergency planning purposes. The objective of...
Real-time, high efficiency neutron spectroscopy has, historically, been a persistent challenge in the field of radiation detection and, for the most part, has gone unsolved. The most promising method to resolve this challenge, is the boron-capture technique using an organic scintillation system (BC-523a). Detectors that utilize this method possess an...
:
________________________________________________________________
David M. Hamby
Real-time, high efficiency neutron spectroscopy has, historically, been
A lack of data concerning tungsten-based medical shields, specifically unit dose transport pigs, may lead to unnecessary exposure to medical personnel. Available research comparing lead to sintered tungsten shows that tungsten is approximately 1.5 - 10.0 times more effective as a radiation shield. However, this research lacks high-energy vs. low-energy...
Fortuitous dosimeters are radiosensitive objects carried by an individual who was exposed to radiation. These objects can be analyzed some time after exposure and the results can be used to aid in calculating radiation fields and doses received by individuals. Items that make good fortuitous dosimeters are those that are...
CR-39 foils were irradiated as part of nuclear accident dosimetry experiments using the Godiva reactor at the Nevada National Security Site and the Caliban and Prospero reactors at the Valduc Centre for Nuclear Studies in France. The irradiated foils were chemically etched using the standard Lawrence Livermore National Laboratory process...
Nonmelanoma skin cancer (NMSC) is the most common malignancy in Caucasian populations. One existing treatment modality for NMSCs is external radiotherapy delivered to the skin cancer tumor by a beta-emitter-containing radioactive skin patch. Alpha emitters, with their higher linear energy transfer than beta particles and shorter range in tissue, make...
Since the International Commission on Radiation Protection (ICRP) recommended a revision to the eye lens dose limits in ICRP Publication 118 (Stewart, 2012) the radiation protection community has conducted many new studies related to eye dosimetry. The recommended reduction of eye lens dose limits may result in the reduction of...
:
______________________________________________________________
David M. Hamby
Abstract:
Since the International Commission on Radiation Protection (ICRP
The Code of Federal Regulations (10CFR20.1201) mandates occupational dose limits to the shallow, lens and deep tissue layers. The NRC-accepted procedure of estimating dose to these layers from contamination events is laborious. The current work aims to further the development of a portable phoswich-style skin dosimeter that will operate in...