Engineered wood composites are used in many structural applications and are intended for dry use. However, these materials may encounter significant amounts of wetting while in service, which can lead to structural failures. This study combined aspects of wood science, mechanics, structural engineering, and mycology to assess changes in material...
The objectives of this study are: (1) to evaluate the effect of reference
displacement on wall behavior under fully reversed cyclic loading using the
CUREE test protocol and (2) to assess damage accumulation (visible fastener
damage and stiffness degradation) for the imposed drift levels. All tests were
conducted on identical...
Heavy timber framing relies primarily on bracing to withstand lateral loads due to earthquakes and wind events. Bracing configurations in heavy timber framed buildings vary widely and include cross bracing, knee bracing, and other geometries. Many heavy timber frames constructed during colonial American times are still standing, exceeding the expected...
The objectives of this study were to evaluate the performance of wood frame shear walls
under monotonic, cyclic and earthquake loads by: (1) estimating the variability of shear wall
performance, (2) comparing the performance of walls under each loading protocol, (3) evaluating
the effects of anchorage on wall performance, and...
The objective of this study was to determine the effect of misplaced hold-downs
on the static and cyclic behavior of wood shear walls. Three shear wall
configurations were considered in this study. The first configuration (control) had
hold-downs at the ends of the wall (wall type 1), the second configuration...
The overall goal of this study was to gain an insight into the load sharing aspect between oriented strand board (OSB) and gypsum wall board (GWB) in shear wall assembly during racking load. More specifically the objectives of the study were to: (1) evaluate qualitatively the load sharing between OSB...
As mass-timber building construction rises around the globe, there exists the need to verify the long-term, in-situ behavior and performance of these structural systems. Structural health monitoring (SHM), generally defined as a damage detection strategy consisting of a network of sensors, a data acquisition system, and algorithms for data analysis,...
Key parts of the lateral force resisting system in wood-frame buildings
are the shearwafls and the connections. The connections in wooden buildings
are the primary source of ductility and energy dissipation; these are essential
properties when buildings are exposed to lateral forces, such as wind and
earthquakes. Shearwall design is...
The overall goal of this study is to evaluate the earthquake performance of wood frame
shear walls, and more specifically: (1) to compare the performance differences of fully and
partially anchored walls under monotonic, cyclic, and earthquake loads, (2) to compare wall
performance under earthquake loads with that of standardized...
The overall goal of this project was to design a wood frame shear wall that could withstand greater displacement before damage occurred to the Gypsum Wall Board (GWB). More specifically, the objectives of the study were: (1) to evaluate damage to the GWB in alternative shear wall designs at 1%,...