Article
 

Experimental Study on Detection of Deterioration in Concrete Using Infrared Thermography Technique

公开 Deposited

可下载的内容

下载PDF文件
https://ir.library.oregonstate.edu/concern/articles/b5644w458

Descriptions

Attribute NameValues
Creator
Abstract
  • Concrete is certainly prone to internal deteriorations or defects during the construction and operating periods. Compared with other nondestructive techniques, infrared thermography can easily detect the subsurface delamination in a very short period of time, but accurately identifying its size and depth in concrete is a very challenging task. In this study, experimental testing was carried out on a concrete specimen having internal delaminations of various sizes and at varying depths. Delaminations at 1 and 2 cm deep showed a good temperature contrast after only 5-minute heating, but delaminations at 3 cm practically identified the value of the temperature contrast from heating of 15 minutes. In addition, the size of the delamination at 3 cm deep could be estimated with a difference of 10% to 28% for 20 minutes of heating. The depth of the delamination was linearly correlated with the increase in its size.
License
Resource Type
DOI
Date Available
Date Issued
Citation
  • Huh, J., Tran, Q. H., Lee, J. H., Han, D., Ahn, J. H., & Yim, S. (2016). Experimental Study on Detection of Deterioration in Concrete Using Infrared Thermography Technique. Advances in Materials Science and Engineering, 1053856. doi:10.1155/2016/1053856
Journal Title
Journal Volume
  • 2016
Journal Issue/Number
  • 1053856
Academic Affiliation
权利声明
Funding Statement (additional comments about funding)
  • This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2014R1A1A2058765) and by 2015 Jeonnam Green Environment Center (JNGEC, Korea).
Publisher
Peer Reviewed
Language
Replaces

关联

Parents:

This work has no parents.