Ocean PHILLS hyperspectral imager: design, characterization, and calibration Public Deposited

http://ir.library.oregonstate.edu/concern/defaults/3j333733f

© 2009 The Optical Society. This work was funded by the Office of Naval Research. We thank Marcos Montes for his contribution in implementing the calibration software and the atmospheric correction. We thank David Kohler (FERI) and Ken Carder and Bob Steward (Univ. So. Florida) for frequent fruitful discussions on the calibration and operation of the PHILLS cameras. The mention of a company or product in this publication does not in any way imply an endorsement of that company or product by the U. S. Naval Research Laboratory.

Descriptions

Attribute NameValues
Creator
Abstract or Summary
  • The Ocean Portable Hyperspectral Imager for Low-Light Spectroscopy (Ocean PHILLS) is a hyperspectral imager specifically designed for imaging the coastal ocean. It uses a thinned, backside-illuminated CCD for high sensitivity and an all-reflective spectrograph with a convex grating in an Offner configuration to produce a nearly distortion-free image. The sensor, which was constructed entirely from commercially available components, has been successfully deployed during several oceanographic experiments in 1999-2001. Here we describe the instrument design and present the results of laboratory characterization and calibration. We also present examples of remote-sensing reflectance data obtained from the LEO-15 site in New Jersey that agrees well with ground-truth measurements.
Resource Type
Date Available
Date Issued
Citation
  • Davis, C. O., Bowles, J., Leathers, R. A., Korwan, D., Downes, T., Snyder, W. A., & Rhea, W. (2002). Ocean PHILLS hyperspectral imager: design, characterization, and calibration. Optics Express, 10(4). Retrieved December 1, 2010, from http://rsd-www.nrl.navy.mil/7230/pdf/20020225_OE.pdf
Keyword
Rights Statement
Publisher
Replaces
Additional Information
  • description.provenance : Submitted by Sue Kunda (sue.kunda@oregonstate.edu) on 2010-12-03T00:19:05Z No. of bitstreams: 1 Davis PHILLS OpticsExpress[1].pdf: 980938 bytes, checksum: 96fdcdbe0376cc42f3c35dcc8ab8d105 (MD5)
  • Optics Express
  • description.provenance : Approved for entry into archive by Sue Kunda(sue.kunda@oregonstate.edu) on 2010-12-03T00:19:38Z (GMT) No. of bitstreams: 1 Davis PHILLS OpticsExpress[1].pdf: 980938 bytes, checksum: 96fdcdbe0376cc42f3c35dcc8ab8d105 (MD5)
  • description.provenance : Made available in DSpace on 2010-12-03T00:19:38Z (GMT). No. of bitstreams: 1 Davis PHILLS OpticsExpress[1].pdf: 980938 bytes, checksum: 96fdcdbe0376cc42f3c35dcc8ab8d105 (MD5) Previous issue date: 2002-02-25
  • Vol. 10 (2002)

Relationships

Parents:

This work has no parents.

Last modified

Downloadable Content

Download PDF

Items