Comparison of pressurized liquid extraction and matrix solid phase dispersion for the measurement of semi-volatile organic compound accumulation in tadpoles Public Deposited

http://ir.library.oregonstate.edu/concern/defaults/5q47rp80v

This is an author's peer-reviewed final manuscript, as accepted by the publisher. The published article is copyrighted by SETAC and published by John Wiley & Sons Ltd. It can be found at:  http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%291552-8618.

Descriptions

Attribute NameValues
Alternative Title
  • Comparison of pressurized liquid extraction and matrix solid-phase dispersion for the measurement of semivolatile organic compound accumulation in tadpoles
Creator
Abstract or Summary
  • Analytical methods capable of trace measurement of semi-volatile organic compounds (SOCs) are necessary to assess the exposure of tadpoles to contaminants as a result of long-range and regional atmospheric transport and deposition. The following study compares the results of two analytical methods, one using pressurized liquid extraction (PLE) and the other using matrix solid phase dispersion (MSPD), for the trace measurement of over 70 SOCs, including current-use pesticides, in tadpole tissue. The MSPD method resulted in improved SOC recoveries and precision compared to the PLE method. The MSPD method also required less time, consumed less solvent, and resulted in the measurement of a greater number of SOCs than the PLE method.
Resource Type
DOI
Date Available
Date Issued
Citation
  • Stanley, K., Simonich, S. M., Bradford, D., Davidson, C. & Tallent-Halsell, N. (2009). Comparison of pressurized liquid extraction and matrix solid-phase dispersion for the measurement of semivolatile organic compound accumulation in tadpoles. Environmental Toxicology and Chemistry, 28(10), 2038–2043. doi:10.1897/08-342.1
Academic Affiliation
Series
Keyword
Rights Statement
Funding Statement (additional comments about funding)
Publisher
Peer Reviewed
Language
Replaces
Additional Information
  • description.provenance : Submitted by Erin Clark (erin.clark@oregonstate.edu) on 2014-12-29T20:47:52Z No. of bitstreams: 3 SimonichStaciEMTComparisonPressurizedLiquid.pdf: 288746 bytes, checksum: 42dfea1a9223d49b66020be184d8d443 (MD5) SimonichStaciEMTComparisonPressurizedLiquid_Figure1.jpg: 131405 bytes, checksum: 52f69a4b7c30ea7b23ac57117daea28d (MD5) SimonichStaciEMTComparisonPressurizedLiquid_Tables1-3.pdf: 61567 bytes, checksum: a90aad9c7c2f02db0b68c1324106ab42 (MD5)
  • description.provenance : Approved for entry into archive by Erin Clark(erin.clark@oregonstate.edu) on 2014-12-29T20:48:09Z (GMT) No. of bitstreams: 3 SimonichStaciEMTComparisonPressurizedLiquid.pdf: 288746 bytes, checksum: 42dfea1a9223d49b66020be184d8d443 (MD5) SimonichStaciEMTComparisonPressurizedLiquid_Figure1.jpg: 131405 bytes, checksum: 52f69a4b7c30ea7b23ac57117daea28d (MD5) SimonichStaciEMTComparisonPressurizedLiquid_Tables1-3.pdf: 61567 bytes, checksum: a90aad9c7c2f02db0b68c1324106ab42 (MD5)
  • description.provenance : Made available in DSpace on 2014-12-29T20:48:09Z (GMT). No. of bitstreams: 3 SimonichStaciEMTComparisonPressurizedLiquid.pdf: 288746 bytes, checksum: 42dfea1a9223d49b66020be184d8d443 (MD5) SimonichStaciEMTComparisonPressurizedLiquid_Figure1.jpg: 131405 bytes, checksum: 52f69a4b7c30ea7b23ac57117daea28d (MD5) SimonichStaciEMTComparisonPressurizedLiquid_Tables1-3.pdf: 61567 bytes, checksum: a90aad9c7c2f02db0b68c1324106ab42 (MD5) Previous issue date: 2009-10

Relationships

In Administrative Set:
Last modified: 07/13/2017 Default
Citations:

EndNote | Zotero | Mendeley

Items