Double-Ended Calibration of Fiber-Optic Raman Spectra Distributed Temperature Sensing Data Public Deposited

http://ir.library.oregonstate.edu/concern/defaults/d217qq40j

This is the publisher’s final pdf. The published article is copyrighted by MDPI Publishing and can be found at:  http://www.mdpi.com/journal/sensors.

Descriptions

Attribute NameValues
Creator
Abstract or Summary
  • Over the past five years, Distributed Temperature Sensing (DTS) along fiber optic cables using Raman backscattering has become an important tool in the environmental sciences. Many environmental applications of DTS demand very accurate temperature measurements, with typical RMSE < 0.1 K. The aim of this paper is to describe and clarify the advantages and disadvantages of double-ended calibration to achieve such accuracy under field conditions. By measuring backscatter from both ends of the fiber optic cable, one can redress the effects of differential attenuation, as caused by bends, splices, and connectors. The methodological principles behind the double-ended calibration are presented, together with a set of practical considerations for field deployment. The results from a field experiment are presented, which show that with double-ended calibration good accuracies can be attained in the field.
Resource Type
DOI
Date Available
Date Issued
Citation
  • van de Giesen, N., Steele-Dunne, S. C., Jansen, J., Hoes, O., Hausner, M. B., Tyler, S., & Selker, J. (2012, May). Double-ended calibration of fiber-optic Raman spectra distributed temperature sensing data. Sensors, 12(5), 5471-5485. doi:10.3390/s120505471
Academic Affiliation
Series
Keyword
Rights Statement
Funding Statement (additional comments about funding)
Publisher
Language
Replaces
Additional Information
  • description.provenance : Submitted by Deanne Bruner (deanne.bruner@oregonstate.edu) on 2012-06-26T18:40:59Z No. of bitstreams: 3 license_rdf: 19965 bytes, checksum: 225316337756db2af069c3edfe03a49f (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) SelkerJohnBioEcoEngineeringDoubleEndedCalibration.pdf: 299076 bytes, checksum: 40176fe91d5a6076b53b6d51c40d18c0 (MD5)
  • description.provenance : Approved for entry into archive by Deanne Bruner(deanne.bruner@oregonstate.edu) on 2012-06-26T18:41:58Z (GMT) No. of bitstreams: 3 license_rdf: 19965 bytes, checksum: 225316337756db2af069c3edfe03a49f (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) SelkerJohnBioEcoEngineeringDoubleEndedCalibration.pdf: 299076 bytes, checksum: 40176fe91d5a6076b53b6d51c40d18c0 (MD5)
  • description.provenance : Made available in DSpace on 2012-06-26T18:41:58Z (GMT). No. of bitstreams: 3 license_rdf: 19965 bytes, checksum: 225316337756db2af069c3edfe03a49f (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) SelkerJohnBioEcoEngineeringDoubleEndedCalibration.pdf: 299076 bytes, checksum: 40176fe91d5a6076b53b6d51c40d18c0 (MD5) Previous issue date: 2012-05

Relationships

In Administrative Set:
Last modified: 07/13/2017

Downloadable Content

Download PDF
Citations:

EndNote | Zotero | Mendeley

Items