Calibrating Single-Ended Fiber-Optic Raman Spectra Distributed Temperature Sensing Data Public Deposited

http://ir.library.oregonstate.edu/concern/defaults/h702q7192

This is the publisher’s final pdf. The published article is copyrighted by the Multidisciplinary Digital Publishing Institute and can be found at:  http://www.mdpi.com/journal/sensors.

Descriptions

Attribute NameValues
Creator
Abstract or Summary
  • Hydrologic research is a very demanding application of fiber-optic distributed temperature sensing (DTS) in terms of precision, accuracy and calibration. The physics behind the most frequently used DTS instruments are considered as they apply to four calibration methods for single-ended DTS installations. The new methods presented are more accurate than the instrument-calibrated data, achieving accuracies on the order of tenths of a degree root mean square error (RMSE) and mean bias. Effects of localized non-uniformities that violate the assumptions of single-ended calibration data are explored and quantified. Experimental design considerations such as selection of integration times or selection of the length of the reference sections are discussed, and the impacts of these considerations on calibrated temperatures are explored in two case studies.
Resource Type
DOI
Date Available
Date Issued
Citation
  • Hausner, M. B., Suarez, F., Glander, K. E., van de Giesen, N., Selker, J. S., & Tyler, S. W. (2011, November). Calibrating single-ended fiber-optic raman spectra distributed temperature sensing data. Sensors, 11(11), 10859-10879. doi:10.3390/s111110859
Academic Affiliation
Series
Keyword
Rights Statement
Funding Statement (additional comments about funding)
Publisher
Language
Replaces
Additional Information
  • description.provenance : Submitted by Deanne Bruner (deanne.bruner@oregonstate.edu) on 2012-06-11T19:18:05Z No. of bitstreams: 1 SelkerJohnBioEcoEngineeringCalibratingSingleEnded.pdf: 511052 bytes, checksum: 165825643cf939f40454e565bdec82e8 (MD5)
  • description.provenance : Made available in DSpace on 2012-06-11T19:18:22Z (GMT). No. of bitstreams: 1 SelkerJohnBioEcoEngineeringCalibratingSingleEnded.pdf: 511052 bytes, checksum: 165825643cf939f40454e565bdec82e8 (MD5) Previous issue date: 2011-11
  • description.provenance : Approved for entry into archive by Deanne Bruner(deanne.bruner@oregonstate.edu) on 2012-06-11T19:18:22Z (GMT) No. of bitstreams: 1 SelkerJohnBioEcoEngineeringCalibratingSingleEnded.pdf: 511052 bytes, checksum: 165825643cf939f40454e565bdec82e8 (MD5)

Relationships

In Administrative Set:
Last modified: 07/13/2017

Downloadable Content

Download PDF
Citations:

EndNote | Zotero | Mendeley

Items