Article
 

Damage Assessment of a Full-Scale Six-Story Wood-Frame Building Following Triaxial Shake Table Tests

Pubblico Deposited

Contenuto scaricabile

Scarica il pdf
https://ir.library.oregonstate.edu/concern/articles/xd07gt60j

Descriptions

Attribute NameValues
Creator
Abstract
  • In the summer of 2009, a full-scale midrise wood-frame building was tested under a series of simulated earthquakes on the world's largest shake table in Miki City, Japan. The objective of this series of tests was to validate a performance-based seismic design approach by qualitatively and quantitatively examining the building's seismic performance in terms of response kinematics and observed damage. This paper presents the results of detailed damage inspections following each test in a series of five shake table tests, and explains their qualitative synthesis to provide design method validation. The seismic test program had two phases. Phase I was the testing of a seven-story mixed-use building with the first story consisting of a steel special moment frame (SMF) and stories 2-7 made of light-frame wood. In Phase II, the SMF was heavily braced such that it effectively became an extension of the shake table and testing was conducted on only stories 2-7, making the building a six-story light-frame multifamily residential building instead of a mixed-use building. All earthquake motions were scalings of the 1994 Northridge earthquake at the Canoga Park recording station with seismic intensities ranging from peak ground accelerations of 0.22 to 0.88 g. The building performed quite well during all earthquakes with damage only to the gypsum wall board (drywall), no sill plate splitting, no nails withdrawing or pulling through the sheathing, no edge tearing of the sheathing, no visible stud splitting around tie-down rods, and reasonable floor accelerations. On the basis of damage inspection, it was concluded that it is possible to design this type of building and keep the damage to a manageable level during major earthquakes by utilizing the new design approach. DOI: 10.1061/(ASCE)CF.1943-5509.0000202. (C) 2012 American Society of Civil Engineers
  • Keywords: Experimentation, Shake table tests, Damage assessment, Wood structures, Performance, Full-scale tests, Damage, Full-scale experiment, Earthquakes, Multi-story buildings, Shake table
Resource Type
DOI
Date Available
Date Issued
Citation
  • van de Lindt, J., Gupta, R., Pei, S., Tachibana, K., Araki, Y., Rammer, D., and Isoda, H. (2012). ”Damage Assessment of a Full-Scale Six-Story Wood-Frame Building Following Triaxial Shake Table Tests.” Journal of Performance of Constructed Facilities, 26(1), 17–25. doi: 10.1061/(ASCE)CF.1943-5509.0000202
Journal Title
Journal Volume
  • 26
Journal Issue/Number
  • 1
Academic Affiliation
Dichiarazione dei diritti
Funding Statement (additional comments about funding)
  • The material presented in this paper is based upon work supported by the National Science Foundation (NSF) under Grant No. CMMI-0529903 (NEES Research) and CMMI-0402490 (NEES Operations).
Publisher
Peer Reviewed
Language
Replaces

Le relazioni

Parents:

This work has no parents.

Elementi