Abstract
  • A source test was conducted to determine the particulate and the total gaseous hydrocarbon emissions from a gas heated veneer dryer. Samples were taken on eight separate days from the exhaust stacks while the dryer was processing Douglas fir veneer. Of the eight days, three was used to determine the gaseous hydrocarbon concentration using a flame ionization hydrocarbon detector and five were used to determine gravimetrically the particulate concentration. Experimental emission rates were 0.87 pounds per hour for particulates and 16.02 pounds per hour for gaseous hydrocarbons.
Resource Type
Date Available
Date Issued
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Academic Affiliation
Non-Academic Affiliation
Subject
Rights Statement
Publisher
Peer Reviewed
Language
Digitization Specifications
  • File scanned at 300 ppi using ScandAll PRO 1.8.1 on a Fi-6670 in PDF format. CVista PdfCompressor 5.0 was used for pdf compression and textual OCR.