Graduate Thesis Or Dissertation
 

Response of skin surface temperature to an application of high voltage pulsed galvanic current (HVPGC) as a treatment method for sports injuries

Público Deposited

Conteúdo disponível para baixar

Baixar PDF
https://ir.library.oregonstate.edu/concern/graduate_thesis_or_dissertations/1c18dk245

Descriptions

Attribute NameValues
Creator
Abstract
  • Ankle injuries account for 10-20% of time loss injuries in sports with almost 85% of these injuries being sprains, the majority of which occur to the lateral ligamentous complex. With statistics such as these it becomes important that the Athletic Trainer establish a method for effective and efficient means to safely rehabilitate injuries. This study was designed to measure the response of skin surface temperature to an application of high voltage pulsed galvanic current (HVPGC). Three hypotheses were tested in this study: 1 ) No significant difference would exist in skin surface temperature response as a result of applying ice or applying ice plus HVPGC. 2) No significant difference would exist in skin surface temperature response patterns over a span of 30 minutes as a result of the application of ice or ice plus H4PGC. 3) No significant difference would exist in skin surface temperature response patterns of male and female subjects over a span of 30 minutes as a result of the application of ice or ice plus HVPGC. Twenty-two healthy adult subjects volunteered to participate in this study. A repeated measures design was used with each subject being tested under each of the testing conditions: 1) a slush bucket cooled to 1-2°C and 2) a slush bucket cooled to 1-2°C with the introduction of a positive polarity HVPGC of 80 pulses per second. Each testing condition was administered one time for 30 minutes with a one week minimun time period between testing conditions. Skin surface temperatures were measured every 2.5 minutes from time 0 through time 30 minutes. An analysis of variance was computed using the treatment conditions and time (0.0, 2.5, 5.0, 7.5, 10.0, 12.5, 15.0, 17.5, 20.0, 22.5, 25.0, 27.5, and 30.0 minutes) as the independent variables. When a significant difference between variables was determined a Scheffe test was conducted to determine significant difference in each testing condition at selected points in time. Within the limitations of this study is was concluded: 1) No significant difference existed in skin temperature response as a result of applying ice or ice plus HVPGC. 2) No significant difference existed in skin surface temperature response patterns over a span of 30 minutes as a result of the application of ice or ice plus HVPGC. 3) No significant difference existed in skin surface temperature response patterns of male and female subjects over a span of 30 minutes as a result of the application of ice or ice plus HVPGC.
Resource Type
Date Available
Date Issued
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Committee Member
Academic Affiliation
Non-Academic Affiliation
Subject
Declaração de direitos
Publisher
Peer Reviewed
Language
Digitization Specifications
  • File scanned at 300 ppi (Monochrome, 256 Grayscale) using Capture Perfect 3.0 on a Canon DR-9050C in PDF format. CVista PdfCompressor 4.0 was used for pdf compression and textual OCR.
Replaces

Relações

Parents:

This work has no parents.

Em Collection:

Itens