Graduate Thesis Or Dissertation

 

Evaluation of cathodic protection in reinforced concrete bridges Public Deposited

Downloadable Content

Download PDF
https://ir.library.oregonstate.edu/concern/graduate_thesis_or_dissertations/3484zm39h

Descriptions

Attribute NameValues
Creator
Abstract
  • Steel corrosion in reinforced concrete is a major concern to transportation agencies nationwide because of the expenses incurred for repair and ultimate shortening of bridge life. Cathodic protection (CP), as a remedy, has been applied to reinforced bridges in the US since 1974. However, application of this technique is largely empirical, lacking fundamental understanding. In order to optimize the performance of a CP system, it is important to monitor the rebar potential with respect to a reliable reference electrode. Moreover, because of potential variation in the concrete, reference cell placement is fundamental to ensure effective protection. The work plan was divided into two parts: laboratory scale experimentation and computer simulation. In the experimentation section, the response of graphite probes was compared to that of an Orion silver-silver chloride electrode. Graphite probes behaved as well as the standard electrode. Furthermore, the home-made graphite probes behaved the same as the commercial ones. This will allow much greater experimental latitude since the home-made probes are much more economical than the commercial ones. A finite difference code was developed to assess the performance of cathodic protection. The potential distribution in a two dimensional geometry of a concrete block with a sprayed zinc anode at one boundary and an iron cathode at the other side was calculated under cathodic protection. The equations were solved by means of a Gauss-Seidel iterative method with the help of an overrelaxation factor. An interval halving method was used to solve for nonlinear boundary condition at the iron. The effects of concrete pore saturation, concrete cover, and applied potential were studied to determine the degree of protection and proper placement of the reference electrode in concrete. Furthermore, a sensitivity analysis was performed versus input parameters: concrete conductivity, oxygen mass transfer coefficient, and oxygen reduction polarization parameters. The results of the simulation showed that the center of the rebar is less protected than the other locations. Therefore, the reference electrode should be located as close to the center as possible.
Resource Type
Date Available
Date Issued
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Academic Affiliation
Non-Academic Affiliation
Subject
Rights Statement
Publisher
Peer Reviewed
Language
Digitization Specifications
  • File scanned at 300 ppi (Monochrome, 256 Grayscale) using Capture Perfect 3.0 on a Canon DR-9050C in PDF format. CVista PdfCompressor 4.0 was used for pdf compression and textual OCR.
Replaces
Additional Information
  • description.provenance : Approved for entry into archive by Patricia Black(patricia.black@oregonstate.edu) on 2012-11-21T19:18:13Z (GMT) No. of bitstreams: 1 AbooameriFarid1995.pdf: 4904773 bytes, checksum: 68a28a7943478638adbaa7f31f0c4edf (MD5)
  • description.provenance : Submitted by Kirsten Clark (kcscannerosu@gmail.com) on 2012-11-14T21:11:35Z No. of bitstreams: 1 AbooameriFarid1995.pdf: 4904773 bytes, checksum: 68a28a7943478638adbaa7f31f0c4edf (MD5)
  • description.provenance : Approved for entry into archive by Patricia Black(patricia.black@oregonstate.edu) on 2012-11-21T21:11:28Z (GMT) No. of bitstreams: 1 AbooameriFarid1995.pdf: 4904773 bytes, checksum: 68a28a7943478638adbaa7f31f0c4edf (MD5)
  • description.provenance : Made available in DSpace on 2012-11-21T21:11:28Z (GMT). No. of bitstreams: 1 AbooameriFarid1995.pdf: 4904773 bytes, checksum: 68a28a7943478638adbaa7f31f0c4edf (MD5) Previous issue date: 1994-09-28

Relationships

Parents:

This work has no parents.

In Collection:

Items