Accounting for Heterogeneity Corrections in Breast Brachytherapy

Público Deposited

Conteúdo disponível para baixar

Baixar PDF
https://ir.library.oregonstate.edu/concern/graduate_thesis_or_dissertations/9p290f68g

Descriptions

Attribute NameValues
Creator
Abstract
  • Purpose: Model-based dose calculation algorithms (MBDCAs) have become clinically available within the past several years in commercially available brachytherapy planning systems. This work investigates the application of a 510(k) approved MBDCA Acuros™ BV and establishes a reproducible method of validation. The research is broken into three primary research goals. The first objective was to focus on helping medical physicists reproducibly validate the implementation of MBDCA in the clinic by using direct measurements and comparison to Monte Carlo (MC). The second objective was to commission a very low energy spectrum using Attila™, the parent software to Acuros™ BV, by comparison to MC. The third area retrospectively examines the application of Acuros™ BV to a large group of previously treated patients by accelerated partial breast irradiation brachytherapy. Methods: A Quality Assurance phantom (QAP) was fabricated by taking a solid (30x30x5 cm3) piece of water and drilling a 3 cm diameter hole to accommodate a variety of pre-manufactured density plugs. The phantom was used to validate the clinical implementation of the commercially available MBDC algorithm AcurosTM BV. Once the QAP was imported into BrachyVision, the AcurosTM BV 192Ir dose distributions were calculated. The QAP was modeled using Monte Carlo N-Particle version 5 (MCNP5) and dose predictions were compared to AcurosTM BV at 0.2 cm increments out to 4.5 cm. Additionally, physical measurements taken using Diode and a MOSFET were also compared to AcurosTM BV. The second part of the investigation used a similar QAP simulated three dimensionally in Attila™. This investigation replaced the 192Ir source with a 50 kVp source spectrum provided by Xoft, Inc. Attila™ and MCNP5 were used to simulate this low energy spectrum as the source in the QAP at multiple points for comparison. The final investigation examined two hundred accelerated partial breast irradiated (APBI) brachytherapy patients that had been treated from 2008 to 2012 by the original TG43 formalism and recalculated using AcurosTM BV. Clinically relevant endpoints such as V100, V90, erythema and moist desquamation were compared between TG43 and Acuros™ BV. Results: Over twenty points extending through different heterogeneities were compared using an 192Ir source and calculated for both AcurosTM BV and MCNP. Physical measurements taken on the QAP using solid-state detectors compared within 1% of Acuros™ BV calculations. The absolute dose of AcurosTM BV compared with MC results varied from -3.0% up to 7.2%. When investigating the impact of heterogeneities from a low kV spectrum, the absolute difference from Attila™ and MC ranged from -15.1% to 9.0%. The final retrospective study showed noticeable changes in recalculated dosimetry, with the most significant changes observed with balloon devices. The difference in dose when AcurosTM BV was subtracted from TG43 calculations showed balloons have reduced skin doses that ranged from 0.4% to 10.2%. The differences for SAVI™ showed skin dose changes from -9.5% to 7.8%. For balloon devices, the average dose differences for V100, V95, V90 were 5.6%, 4.9% and 3.8%, respectively. The SAVI™ dose differences for V100, V95, V90 were 2.2%, 2.1%, and 1.8%, respectively. Conclusions: A phantom was fabricated to serve as a tool for clinical medical physicists to efficiently and reproducibly validate the commissioning of MBDCAs. This QAP aids in a fully inclusive system check from CT acquisition, to AcurosTM BV calculations and finally diode or MOSFET measurements. Commissioning for very low energy spectrum, such as eBx, was accomplished by importing this phantom into Attila™ and comparing to MCNP calculations when encountering heterogeneities. The final retrospective study suggest further investigation is needed to assign uniform densities to heterogeneities encountered in the patient's CT images. The recalculated patient dose using Acuros™ BV did predict a reduction in dose at key points, such as tissue-air interface, V100 and V90 coverage, however, acute and chronic skin dose thresholds showed no trending in data and were not predictable.
License
Resource Type
Date Available
Date Issued
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Committee Member
Academic Affiliation
Non-Academic Affiliation
Declaração de direitos
Publisher
Peer Reviewed
Language
Replaces

Relações

Parents:

This work has no parents.

Em Collection:

Itens