Abstract or Summary
  • A primarily software based Fourier Deep Level Transient Spectroscope (FDLTS) is built. The raw capacitance transient is acquired and digitized using capacitance meter HP4280A whereas the signal analysis is done using a customized software module. The software module calculates both the conventional DLTS spectrum and the Fourier DLTS spectrum. This home-made FDLTS set up was compared to a commercial conventional box-car DLTS system (Sula Technology's DLTS) as well as to a commercial Fourier DLTS system (Bio-rad) and it was found to be either equivalent to the commercial systems or even better in some respects. In one case, Fourier analysis using the home-made setup, led to the detection of a trap completely undetected by the commercial conventional DLTS. The FDLTS system together with the commercial conventional DLTS were used to study possible gold contamination in an industrial process. The study was accomplished by comparing conventional and Fourier DLTS spectra and corresponding calculated trap properties using Schottky barrier diodes fabricated on the suspect wafers and an intentionally gold diffused reference sample wafer. During the investigation minority carrier emission in DLTS using Schottky barrier diodes was observed. The study revealed the presence of some possible gold-like contamination which trapped minority carriers (i.e. electrons) in p type silicon.
Resource Type
Date Available
Date Copyright
Date Issued
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Academic Affiliation
Non-Academic Affiliation
Subject
Rights Statement
Peer Reviewed
Language
Digitization Specifications
  • File scanned at 300 ppi (Monochrome, 8-bit Grayscale, 24-bit Color) using ScandAll PRO 1.8.1 on a Fi-6670 in PDF format. CVista PdfCompressor 4.0 was used for pdf compression and textual OCR.
Replaces
Additional Information
  • description.provenance : Approved for entry into archive by Patricia Black(patricia.black@oregonstate.edu) on 2012-07-31T18:50:23Z (GMT) No. of bitstreams: 1 DivekarPrasadK2003.pdf: 3206215 bytes, checksum: 06ce175bd3d743fe16865e807cdfd5b4 (MD5)
  • description.provenance : Approved for entry into archive by Patricia Black(patricia.black@oregonstate.edu) on 2012-07-31T18:47:28Z (GMT) No. of bitstreams: 1 DivekarPrasadK2003.pdf: 3206215 bytes, checksum: 06ce175bd3d743fe16865e807cdfd5b4 (MD5)
  • description.provenance : Made available in DSpace on 2012-07-31T18:50:23Z (GMT). No. of bitstreams: 1 DivekarPrasadK2003.pdf: 3206215 bytes, checksum: 06ce175bd3d743fe16865e807cdfd5b4 (MD5) Previous issue date: 2002-07-03
  • description.provenance : Submitted by Sergio Trujillo (jstscanner@gmail.com) on 2012-07-30T23:48:08Z No. of bitstreams: 1 DivekarPrasadK2003.pdf: 3206215 bytes, checksum: 06ce175bd3d743fe16865e807cdfd5b4 (MD5)

Relationships

In Administrative Set:
Last modified: 08/09/2017

Downloadable Content

Download PDF
Citations:

EndNote | Zotero | Mendeley

Items