  • Because of its characteristics, the square-loop magnetic core can be used as the basic device in a logic system. A magnetomotive force (mmf) which is below the threshold mmf of such a core will cause a negligible, nonpermanent amount of flux change in the core; and information signals can be distinguished by the amount of flux change they produce in the core. The remanent flux in a magnetic core can be in the clockwise or counterclockwise direction, and the binary information signals ONE and ZERO can be represented by these two directions of flux. The transfer of information in a logic system will introduce noise and cause losses, and the ability of the circuits in a system to respond properly to degraded signals will be determined largely by the transfer characteristics of the circuits. The transfer process is shown to be basically identical for three examples of magnetic-core shift registers, and it is shown that there must be an imbalance of the number of turns on the windings in the coupling loop between a transmitting and a receiving core. For economic reasons this winding imbalance is undesirable, and a circuit requiring only single-turn windings in the coupling loop is proposed. An experimental investigation of the proposed circuit showed that its transfer characteristics are determined by the resistance and inductance in the coupling loop and the amplitude of the current pulse driving the circuit. Voltage waveforms of the circuit seem to indicate that the inductance, which is normally assumed to be detrimental to the circuit operation, might have an optimum value which would be beneficial to the transfer process.
Resource Type
Date Available
Date Copyright
Date Issued
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Academic Affiliation
Non-Academic Affiliation
Subject
Rights Statement
Peer Reviewed
Language
Digitization Specifications
  • File scanned at 300 ppi using Capture Perfect 3.0 on a Canon DR-9050C in PDF format. CVista PdfCompressor 5.0 was used for pdf compression and textual OCR.
Replaces
Additional Information
  • description.provenance : Submitted by Madison Medley (mmscannerosu@gmail.com) on 2014-05-13T21:06:05Z No. of bitstreams: 1 LandgrafRichardC1965.pdf: 624597 bytes, checksum: 09e2344846b49d12f539d8d6017adfde (MD5)
  • description.provenance : Approved for entry into archive by Katy Davis(kdscannerosu@gmail.com) on 2014-05-14T16:26:43Z (GMT) No. of bitstreams: 1 LandgrafRichardC1965.pdf: 624597 bytes, checksum: 09e2344846b49d12f539d8d6017adfde (MD5)
  • description.provenance : Approved for entry into archive by Patricia Black(patricia.black@oregonstate.edu) on 2014-05-14T14:59:35Z (GMT) No. of bitstreams: 1 LandgrafRichardC1965.pdf: 624597 bytes, checksum: 09e2344846b49d12f539d8d6017adfde (MD5)
  • description.provenance : Made available in DSpace on 2014-05-14T16:26:43Z (GMT). No. of bitstreams: 1 LandgrafRichardC1965.pdf: 624597 bytes, checksum: 09e2344846b49d12f539d8d6017adfde (MD5) Previous issue date: 1964-06-26

Relationships

In Administrative Set:
Last modified: 08/04/2017

Downloadable Content

Download PDF
Citations:

EndNote | Zotero | Mendeley

Items