Graduate Thesis Or Dissertation
 

Performance and flow stability characteristics in two-phase confined impinging jets

Öffentlich Deposited

Herunterladbarer Inhalt

PDF Herunterladen
https://ir.library.oregonstate.edu/concern/graduate_thesis_or_dissertations/ns0648657

Descriptions

Attribute NameValues
Creator
Abstract
  • Advances in electronics fabrication, coupled with the demand for increased computing power, have driven the demand for innovative cooling solutions to dissipate waste heat generated by these devices. To meet future demands, research and development has focused on robust and stable two-phase heat transfer devices. A confined impinging jet is explored as means of utilizing two-phase heat transfer while minimizing flow instabilities observed in microchannel devices. The test configuration consists of a 4 mm diameter jet of water that impinges on a 38 mm diameter heated aluminum surface. Experimental parameters include inlet mass flow rates from 150 to 600 g/min, nozzle-to-surface spacing from 1 to 8 mm, and input heat fluxes from 0 to 90 W/cm2. Results were used to assess the influence of the testing parameters on the heat transfer performance and stability characteristics of a two-phase confined impinging jet. Stability characteristics were explored using power spectral densities (PSDs) of the inlet pressure time series data. Confined impinging jets, over the range of conditions tested, were found to be stable and an efficient means of removing large amounts of waste heat. The radial geometry of the confined jet allows the fluid to expand as it flows radially away from the nozzle, which suppresses instabilities found in microchannel array geometries. Conditions of the heater surface were found to strongly influence two-phase performance. Analysis of PSDs, for stable operation, showed dominate frequencies in the range of 1-4 Hz, which were attributed to generated vapor expanding in the outlet plenum and the subsequent collapse as it condensed. A stability indicator was developed by inducing artificial instabilities into the system by varying the amount of cross sectional area available for outlet vapor removal and compared to the results for stable operation.
License
Resource Type
Date Available
Date Issued
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Committee Member
Academic Affiliation
Non-Academic Affiliation
Subject
Urheberrechts-Erklärung
Publisher
Peer Reviewed
Language
Replaces

Beziehungen

Parents:

This work has no parents.

In Collection:

Artikel