Sample entraining multi-electrode plasma sources for atomic emission spectroscopy

Público Deposited

Contenido Descargable

Descargar PDF
https://ir.library.oregonstate.edu/concern/graduate_thesis_or_dissertations/x920g060m

Descriptions

Attribute NameValues
Creator
Abstract
  • Plasma sources with multiple electrodes have been developed and characterized in this research for atomic emission spectroscopy. Multi-electrode plasma sources use electrodes to shape the plasma in order to continuously entrain a sample stream in the center of hot plasma, in a manner similar to an inductively coupled plasma (ICP) source. By changing the electrode spacings, the residence time can be readily adjusted even during plasma operation. Fora 25-mm plasma length, a relatively long residence time of the analyte species (23 msec) in the plasma was calculated, indicating sufficient time for desolvation, vaporization, and atomization of the sample. For a 30-mm plasma length, the interference effect of either phosphate or aluminum on calcium emission at 393.37 nm is insignificant over the entire vertical region of the plasma. The effect of an easily ionized element (EIE) is to generally enchance Ca(II) emission in the lower regions, and to depress the emission in the higher regions in the plasma, which is in general agreement with observations in an ICP. Under an assumption of local thermal equilibrium (LTE), the Fe excitation temperature and the electron number density in the center of the plasma at 8 mm above the top of the quartz tube are 5000 K and 1.0x10¹⁵ cm⁻³ for a 30-mm plasma. When current, gas flow rate, and plasma length are varied, the spatial emission profiles reflect many of the characteristics associated with an ICP. The short term stability of the plasma with a blank solution is better than 2% (relative standard deviation). A total of less than 6 L/min of argon gas is required to operate the plasma. With the vertical 4-electrode plasma source, 4 to 5 orders of magnitude of linear dynamic range are obtained and detection limits for 12 elements are comparable to those obtained with an ICP.
Resource Type
Fecha Disponible
Fecha de Emisión
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Academic Affiliation
Non-Academic Affiliation
Subject
Declaración de derechos
Publisher
Peer Reviewed
Language
Digitization Specifications
  • File scanned at 300 ppi (Monochrome) using Capture Perfect 3.0.82 on a Canon DR-9080C in PDF format. CVista PdfCompressor 4.0 was used for pdf compression and textual OCR.
Replaces

Relaciones

Parents:

This work has no parents.

En Collection:

Elementos