Automatic time correction for interconnected power system operation Public Deposited

http://ir.library.oregonstate.edu/concern/graduate_thesis_or_dissertations/zs25xd156

Descriptions

Attribute NameValues
Creator
Abstract or Summary
  • The North American interconnected power systems continuously attempt to hold power system time as close to standard time as possible. All inherent problems associated with normal power system operation make this a difficult task. System time is presently allowed to deviate from standard time by up to two seconds before steps are taken to correct the time error. Present correction methods are manual, time consuming and add to existing operating problems which leads us to the conclusion that the advantages of power system interconnection impose more stringent requirements on load and frequency control. Without precise control of generation and frequency, undesired tie-line flows will result. The Tie-Line-Bias mode of control is examined in detail, with emphasis on present means of controlling system time error. A design concept for automatic system time correction is presented which if accepted by the utilities would eliminate manual initiation of frequency offset periods.
Resource Type
Date Available
Date Copyright
Date Issued
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Academic Affiliation
Non-Academic Affiliation
Subject
Rights Statement
Peer Reviewed
Language
Digitization Specifications
  • File scanned at 300 ppi (Monochrome) using Capture Perfect 3.0.82 on a Canon DR-9080C in PDF format. CVista PdfCompressor 4.0 was used for pdf compression and textual OCR.
Replaces
Additional Information
  • description.provenance : Approved for entry into archive by Patricia Black(patricia.black@oregonstate.edu) on 2014-01-28T15:04:31Z (GMT) No. of bitstreams: 1 ThureinIngo1972.pdf: 927567 bytes, checksum: ed67a3afb74b8122efe6c3452fbc2349 (MD5)
  • description.provenance : Made available in DSpace on 2014-02-03T17:30:07Z (GMT). No. of bitstreams: 1 ThureinIngo1972.pdf: 927567 bytes, checksum: ed67a3afb74b8122efe6c3452fbc2349 (MD5) Previous issue date: 1972-05-08
  • description.provenance : Submitted by Georgeann Booth (gbscannerosu@gmail.com) on 2014-01-25T00:43:39Z No. of bitstreams: 1 ThureinIngo1972.pdf: 927567 bytes, checksum: ed67a3afb74b8122efe6c3452fbc2349 (MD5)
  • description.provenance : Approved for entry into archive by Katy Davis(kdscannerosu@gmail.com) on 2014-02-03T17:30:07Z (GMT) No. of bitstreams: 1 ThureinIngo1972.pdf: 927567 bytes, checksum: ed67a3afb74b8122efe6c3452fbc2349 (MD5)

Relationships

Parents:

This work has no parents.

Last modified

Downloadable Content

Download PDF

Items