Technical Report
 

Lateral bearing strength of fasteners in lumber-plywood joints treated with fire retardants

Public Deposited

Contenu téléchargeable

Télécharger le fichier PDF
https://ir.library.oregonstate.edu/concern/technical_reports/kh04dq911

Descriptions

Attribute NameValues
Creator
Abstract
  • Joints were fabricated from different combinations of untreated and fire-retardant- treated (FRT) Douglas-fir dimension lumber and 3/8-inch plywood. Eight types of fasteners and three fire-retardant treatments were tested. Joint specimens were exposed 2 and 7 years in cold, standard, and warm-humid conditions, then tested in lateral bearing. Best overall performance was from joints made with 6d hot-dipped galvanized nails; 6d monel nails were next best. Although results from several types of fasteners used in treated wood and exposed in cold and standard conditions were as good as results obtained from untreated controls, most specimens exposed in warm, humid conditions were reduced in strength; some were reduced to zero strength.
Resource Type
Date Available
Date Issued
Academic Affiliation
Series
Subject
Déclaration de droits
Publisher
Language
File Format
File Extent
  • 1627175 bytes
Digitization Specifications
  • Master files scanned at 600 ppi (256 Grayscale) using Capture Perfect 3.0 on a Canon DR-9080C in TIF format. PDF derivative scanned at 300 ppi (256 Grayscale), using Capture Perfect 3.0, on a Canon DR-9080C. CVista PdfCompressor 3.1 was used for pdf compression and textual OCR.