  • Purpose: To compare target dose conformality and OAR sparing afforded by VMAT and HT for pancreatic cancer. Materials and Methods: A retrospective planning study was performed in 18 patients. Total treatment dose was 59.4Gy. OAR and PTV mean doses, conformity indices, isodose volumes, and integral doses were compared. The relationship between tumor volume, patient circumference, and these variables was also evaluated. Results: Mean doses to the left kidney (p<.001), right kidney (p<.001), and liver (p<.001) were smaller with VMAT. The mean dose to the PTV was smaller with HT (p=.002). The large field VMAT resulted in a smaller CI percent deviation from 1.0 (p=.025). There was no significant difference for the boost plan (p=.092). Integral dose was significantly lower with VMAT (p<.001). Integral dose was lower for smaller tumor volumes and patent circumferences with both techniques. Conclusion: There appears to be an advantage in using VMAT over HT in reducing radiation doses to the liver and kidneys, in obtaining tighter isodose volumes, and in obtaining a lower integral dose. VMAT may provide superior conformity indices for larger doses, but the techniques are comparable for low doses. Smaller tumor volume and patient circumference result in lower integral doses with both techniques.
Resource Type
Date Available
Date Copyright
Date Issued
Degree Level
Degree Name
Advisor
Non-Academic Affiliation
Keyword
Rights Statement
Language
Replaces
Additional Information
  • description.provenance : Made available in DSpace on 2015-06-03T20:44:23Z (GMT). No. of bitstreams: 1 OgnjenovicSanja2015.pdf: 445916 bytes, checksum: 46d0658c3b583dead4b2245da2c4da51 (MD5)
  • description.provenance : Submitted by Sanja Ognjenovic (ognjenos@onid.orst.edu) on 2015-06-03T18:39:48Z No. of bitstreams: 1 OgnjenovicSanja2015.pdf: 445916 bytes, checksum: 46d0658c3b583dead4b2245da2c4da51 (MD5)
  • description.provenance : Approved for entry into archive by Patricia Black(patricia.black@oregonstate.edu) on 2015-06-03T20:44:23Z (GMT) No. of bitstreams: 1 OgnjenovicSanja2015.pdf: 445916 bytes, checksum: 46d0658c3b583dead4b2245da2c4da51 (MD5)

Relationships

In Administrative Set:
Last modified: 07/27/2017

Downloadable Content

Download PDF
Citations:

EndNote | Zotero | Mendeley

Items