Undergraduate Thesis Or Project
 

Fouling Prevention_Theisis Presentation 2014_ Gollmann.pptx.pdf

Public Deposited

Downloadable Content

Download PDF
https://ir.library.oregonstate.edu/concern/undergraduate_thesis_or_projects/wp988q639

Descriptions

Attribute NameValues
Creator
Abstract
  • Forward osmosis provides a low energy alternative for waste water purification. One of the major issues facing this process is the formation of a foulant layer preventing fluid transfer across the membrane. In recent studies, a conductive layer added to the membrane surface allowing an electric charge to be present on the membrane, has been shown to decrease the rate of mineral fouling in reverse osmosis membranes. Through the application of a conductive layer made of carbon nanotubes on Hydration Technology Innovations, LLC. thin film composite membrane, the applicability of the charged surface and its effects on mineral fouling was explored for forward osmosis membranes. Extensive testing was done by placing both positive and negative charges on the membrane with varying voltage potentials. This method of fouling prevention was found to have little observable effect on the membranes resistance to mineral foulants.
  • Keywords: Forward osmosis, Charged membrane surface, Fouling, Mineral scaling
  • Keywords: Forward osmosis, Charged membrane surface, Fouling, Mineral scaling