mirage   mirage   mirage

Galvanostatic control of ion selective electrodes with the solvent polymeric membrane

DSpace/Manakin Repository

Show simple item record

dc.contributor.advisor Shvarev, Alexey Y.
dc.creator Perera, Hasini R.
dc.date.accessioned 2009-06-23T23:08:37Z
dc.date.available 2009-06-23T23:08:37Z
dc.date.copyright 2009-05-26
dc.date.issued 2009-06-23T23:08:37Z
dc.identifier.uri http://hdl.handle.net/1957/11915
dc.description Graduation date: 2010 en
dc.description.abstract Detection technique that proposed utilizing electrochemically controlled, reversible ion extraction into polymeric membrane in an alternating galvanostatic/ potentiostatic mode was introduced. This method is studied in detail to comprehend the advantages of the novel sensor (pulstrode) compared to the potentiometric ion selective electrode (ISE), studies included possible applications and limitations. Solvent polymeric membrane of the pulstrode contains a highly lipophilic electrolyte and, therefore does not possess spontaneous ion exchange properties. As a consequence pulstrodes have the ability to determine unbiased selectivity coefficients without the careful counterbalancing of transmembrane ionic fluxes. In contrast to classical ISEs they work under asymmetric conditions. Therefore pulstrodes offer simplicity in the determination of selectivity and the results obtained are prone to less error. Further studies with K⁺, Ag⁺ and Ca²⁺ selective electrodes reveal that pulstrodes yield the same or slightly favorable unbiased selectivity coefficients than the previously reported literature values. Since pulstrodes were demonstrated as reliable sensor to determine unbiased selectivity of neutral carriers, they were used to screen potential anion carriers. Selectivity coefficients for [12]-Mercuracarborand-4 was determined using pulstrodes as well as classical ISEs indicating that it has high selectivity towards I⁻. MC4 may be the most selective I⁻ carrier known to date. Ultimately various aspects of the development of reliable, robust and comparatively maintenance free solid contact sensors using conducting polymer as the transduction layer were considered on a model system. Sodium selective pulstrodes based on poly(3,4-ethylendioxythiophene)-poly(styrene sulfonate) (PEDOT:PSS) was identified as the best performing sensor and a protamine selective solid contact pulstrode was fabricated using PEDOT:PSS as the transduction layer. This solid contact pulstrode exhibit a substantial improvement of the low detection limit (0.03 mg/L). en
dc.language.iso en_US en
dc.subject Ion Selective Electrode en
dc.subject Unbiased Selectivity en
dc.subject Solid Contact Pulstrodes en
dc.subject Ionophore en
dc.subject.lcsh Electrodes, Ion selective en
dc.subject.lcsh Ionophores en
dc.title Galvanostatic control of ion selective electrodes with the solvent polymeric membrane en
dc.type Thesis/Dissertation en
dc.degree.name Doctor of Philosophy (Ph. D.) in Chemistry en
dc.degree.level Doctoral en
dc.degree.discipline Science en
dc.degree.grantor Oregon State University en
dc.contributor.committeemember Westall, John
dc.contributor.committeemember Remcho, Vincent
dc.contributor.committeemember Lerner, Michael M.
dc.contributor.committeemember Hackleman, David


The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Search ScholarsArchive@OSU


Advanced Search

Browse

My Account

Statistics