Graduate Thesis Or Dissertation
 

Brian_Collins_Liscense_Agreement.pdf

Public Deposited

Downloadable Content

Download PDF
https://ir.library.oregonstate.edu/concern/graduate_thesis_or_dissertations/8623j077p

Descriptions

Attribute NameValues
Creator
Abstract
  • Reflux condensation tests examining steam condensation in a PWR steam generator (SG) were conducted at the Oregon State University (OSU) Advanced Plant Experiment (APEX) Test Facility from 2005 through 2007. The experimental data collected will provide a basis to assess TRACE steam generator modeling techniques and assist in development of improved models for condensation and steam generator thermal-hydraulics. The data collected using the APEX facility is also applied to the EPR reactor design. During a small break loss of coolant accident, reflux condensation may be used in removing the decay heat after reactor shutdown. It has been determined that the decay heat generated after shutdown can be removed by controlling the secondary side pressure to create a temperature difference.
Keyword
Rights Statement
Peer Reviewed

Relationships

Parents:

Items