This paper highlights the development of a rapid visual screening (RVS) tool to quickly identify, inventory, and rank residential buildings that are potentially seismically hazardous, focusing on single-family, wood-frame dwellings with plan irregularity. The SAPWood software was used to perform a series of nonlinear time-history analyses for 480 representative models,...
With growing interest in mass timber, especially mass timber panels (MTP), there has been a need to better understand their structural properties. One of the most versatile uses for MTP are as floor systems. Under new code provisions, these floors can be utilized in new and taller building types, but...
Ten full-size (3.7×4.9m) plywood roof diaphragms were constructed using metal-plate-connected (MPC) common and hip wood trusses or joists, typical of single-family dwelling (SFD) construction. The specimens included three gable roof slopes of 33, 67, and 100%, a hip roof of 33% slope, and a flat roof, with a horizontal bottom...
The objective of this study was to compare structural load path and system behavior of a light-frame (LF) and a timber frame (TF) structure. This load path analysis is part of a broader research effort that compares LF to TF residential structures. Structural analysis software was used to create a...
Civil engineers are aware of the impacts of structures on the global environment but the environmental impacts of a fire within these structures remains unknown. Fires present a unique hazard as it is difficult to predict the probability of the occurrence and the intensity. Traditional methods to identify the environmental...
Post-tensioned (PT) self-centering shear walls were designed to reduce structural damage from seismic activity. However, these lateral force resistant systems experience post-tension loss negatively affecting the re-centering capability due to delayed deformations experienced by engineered wood products over time. The long-term mechanical response of mass-timber panels to in-plane PT loads...
Conflicts and disasters displace millions of populations worldwide. There is a need for rapid and affordable housing to cater to the needs of the displaced and unhoused population. Experience from previous post-disaster responses shows that temporary housing should be rapidly deployable, planned for months to years, and should be environmentally...
The objectives of this study were to evaluate the performance of wood-frame shear walls under monotonic, cyclic, and earthquake loads by: 1) comparing performance under each loading protocol; 2) evaluating effects of anchorage; and 3) eval-uating performance qualitatively and quantitatively with respect to code-defined performance measures. Tests were conducted on...
Seismic design of wood-frame single-family dwellings’ (WFSFD) lateral force–resisting systems requires determination of the stiffness of horizontal diaphragms and shearwalls. During design, sizes and locations of shearwall openings are often changed, altering shearwall stiffness and loads and requiring a significant redesign effort. Rigid and tributary area method analyses are examined...
Timber-concrete composite (TCC) solutions originated in the early twentieth century. There has been a renewed interest in TCC solutions in modern mass timber buildings, especially for floor systems. However due to lack of data, design standards, and code acceptance, TCC solutions require that new mass timber solutions be tested, and...
This thesis focuses on the fundamental behavior of CLT floor-to-wall connections during a fire.
Cross-laminated timber (CLT) panelized structures rely on floor-to-wall connections for the load path and stability of the structure. Additionally, the fire performance of these connections is critical to prevent horizontal or vertical fire spread within these...
This study investigated the effect of exposure to elevated temperature on the yield strength of single-shear nail connections when subjected to lateral loading. Solid sawn lumber and laminated veneer lumber were used as framing members and two different thicknesses of both oriented strand board and plywood were used as the...