The objective of this study was to investigate load paths in an existing light-frame wood structure with complex geometry, using previously established computer modeling methods. The structural model is derived from an existing, multi-level residence located in Corvallis, Oregon. For the purpose of this study, the existing structure was simplified...
This thesis focuses on the fundamental behavior of CLT floor-to-wall connections during a fire.