A study of nucleate boiling of water, four alcohols and
three ethanol-water mixtures was conducted in a vertical
thermosiphon reboiler. The test section consisted of a 1/2-
inch diameter electrically heated stainless-steel rod
jacketed by a 15-inch long pyrex glass tube. Two different
inside diameters of the glass tube corresponding...
Nucleate boiling of water in a vertical annulus was
studied. The test section was entirely of stainless steel
construction and was formed by a length of stainless steel
tubing with a stainless steel heater rod centered in it. Two
test sections with length to diameter ratios of 18 and 33...
The fouling of cooling tower water was investigated as
a function of heater surface temperature and water quality.
In particular, the effects on fouling of the addition of
calcium in excess of the amounts required for saturation
were examined.
First, the average bulk water temperature was 97 ± 1
degree...
The effects of mass flow rate and subchannel configuration on
the turbulent interchange between adjacent subchannel in simulated
rod bundle were investigated.
The simulated rod bundle was made by arranging seven 1.913 cm
diameter acrylic plastic rods in an equilateral triangular pattern in a
tube 8.89 cm inside diameter.
The...
Deposition characteristics of magnesium silicate and calcium carbonate on a heated surface in cooling tower water using city water as make-up was investigated. Flow velocity, bulk temperature and calcium hardness were maintained constant at 5.3 ft/ sec, 95°F and 150 ppm as CaCO₃ respectively whereas surface temperature varied from 105°F...