A study of nucleate boiling of water, four alcohols and
three ethanol-water mixtures was conducted in a vertical
thermosiphon reboiler. The test section consisted of a 1/2-
inch diameter electrically heated stainless-steel rod
jacketed by a 15-inch long pyrex glass tube. Two different
inside diameters of the glass tube corresponding...
The fouling characteristics of simulated cooling tower water flowing over a heated metallic surface has been studied. The bulk temperature of the water was maintained around 95°F. Mainly three different water qualities with respect to calcium hardness level were investigated. The pH was controlled by the addition of hydrochloric acid....
Nucleate boiling of water in a vertical annulus was
studied. The test section was entirely of stainless steel
construction and was formed by a length of stainless steel
tubing with a stainless steel heater rod centered in it. Two
test sections with length to diameter ratios of 18 and 33...
Momentum transfer in an annular duct with upward gas-Iiquid
flow was studied under the condition that the liquid flowed as a film
only on the inner core of the annulus, the outer wall remaining dry.
Previous workers have studied climbing and falling liquid
films in tubes or on vertical planes....
The fouling of cooling tower water was investigated as
a function of heater surface temperature and water quality.
In particular, the effects on fouling of the addition of
calcium in excess of the amounts required for saturation
were examined.
First, the average bulk water temperature was 97 ± 1
degree...
Drop size distributions produced by the turbulent pipe flow of
dispersions of immiscible liquids were measured photographically.
A mathematical model was developed which predicted both the shape
of the experimentally observed distributions and the experimentally
observed kinetics of the breakup process.
The mutually saturated water and organic phases were pumped...