Heavy timber framing relies primarily on bracing to withstand lateral loads due to earthquakes and wind events. Bracing configurations in heavy timber framed buildings vary widely and include cross bracing, knee bracing, and other geometries. Many heavy timber frames constructed during colonial American times are still standing, exceeding the expected...
Light-frame construction practices and materials have changed greatly
over the past 100 years. Contemporary research has focused on modern construction; thus, we know a great deal about the behavior of modern lightframe buildings under lateral forces. However, there are many light-frame buildings that were built prior to the introduction of...
Capacity of transverse 1950's vintage reinforced concrete deck girder bridge bent caps with large straight bar anchorages were investigated and evaluated. Eleven subassemblage column specimens were examined with different anchorage lengths, bar groupings, amount of transverse steel, and externally applied axial force. Test results showed an increase in anchorage capacity...
Article 1: Behavior of Epoxy Injected Diagonally Cracked Full-Scale CRC Deck-Girders.
Many cast-in place reinforced concrete deck-girder bridges (RCDG) remain in the national inventory and exhibit diagonal cracking. Epoxy injection has been in use for several decades as a method for sealing diagonal cracks, but the effects on girder behavior...
In recent years confinement requirements for concrete columns have increased in seismic regions. Steel jackets are one way to confine reinforced concrete columns. The increased confinement provides additional strength and ductility for the columns during seismic events. For reinforced concrete columns with steel jackets, there are different section properties in...
Current ACI design provisions for shear in reinforced concrete (RC) beams strengthened
with externally bonded carbon fiber-reinforced polymer (CFRP) U-wraps may not adequately account for the effect of scale. This paper describes tests of 6 geometrically scaled beams to identify possible scale effects of such beams. Results indicated that effective...
Long-term durability of surface-bonded carbon fiber-reinforced polymer (CFRP) U-wraps for shear strengthening of reinforced concrete (RC) bridge members remains uncertain due to the limited field experience with these materials. This paper provides experimental results from the testing of full-scale RC bridge girder specimens after exposure to prolonged freeze-thaw cycling. CFRP...
A methodology was developed to permit rectification and metrification of digital images of steel truss gusset plate connections. The approach will enable rapid and accurate collection of field measurements as compared to traditional methods to enable structural evaluation of gusset plate connections. The program enables the operator to quickly create...
Ponding of water on roof systems leading to collapse causes expensive damage and jeopardizes the life safety of building occupants. Current building codes and design specifications for flat roof systems offer minimal guidance in designing for ponding loads. The present research investigated ponding load effects on a long span, lightweight...
Infrastructures along the Oregon Coast are vulnerable to seismic events in the Cascadia Subduction Zone that could generate large tsunamis. Bridges along the coast are an important part of the transportation and lifeline system in the area. The major damages on these bridges due to earthquake and/or tsunami would result...