Tornadoes represent a unique natural hazard because of the very low probability of
occurrence, short warning times (on the order of only a few minutes), and the intense and
destructive forces imposed on engineered and non-engineered buildings. The very low-probability very high-consequence nature of a tornado strike makes designing for...
This paper highlights the development of a rapid visual screening (RVS) tool to quickly identify, inventory, and rank residential buildings that are potentially seismically hazardous, focusing on single-family, wood-frame dwellings with plan irregularity. The SAPWood software was used to perform a series of nonlinear time-history analyses for 480 representative models,...
This paper highlights the development of a rapid visual screening (RVS) tool to quickly identify, inventory, and rank residential buildings that are potentially seismically hazardous, focusing on single-family, wood-frame dwellings with plan irregularity. The SAPWood software was used to perform a series of nonlinear time-history analyses for 480 representative models,...
Compression perpendicular to grain (C┴) of wood is an important property and has a drastic effect on serviceability of the structure. Typical C┴ loading scenarios include the bottom chord of a truss resting on the top plate of a shear wall and chords of a shear wall resting on the...
Monotonic and cyclic tests were carried out to determine strength and stiffness characteristics of 2.44 m (8 ft) long shear connections with 8 mm and 10 mm diameter self-tapping screws. The goal of this research is to compare test values of cross-laminated timber (CLT) diaphragm connections in seismic force-resisting systems...
Current compression perpendicular-to-grain (C-perpendicular to) design values for wood members are based on mean stress obtained from ASTM D143 specimen. The standard ASTM test with metal on wood bearing has limited applicability in modern construction assemblies with C-perpendicular to loading scenarios. Previous work has shown that end-bearing conditions and wood-on-wood...
Current compression perpendicular-to-grain (C⊥) design values for wood members are based on mean stress obtained from ASTM D143 specimen. The standard ASTM test with metal on wood bearing has limited applicability in modern construction assemblies with C⊥ loading scenarios. Previous work has shown that end-bearing conditions and wood-on-wood C⊥ bearing...
Tsunamis have devastated coastal regions worldwide, with the most recent being the result of the Great Tohoku Japan earthquake and tsunami, which was a M9.0 undersea megathrust earthquake that occurred off the east coast of Japan on March 11, 2011. In this study, a fragility formulation is utilized to develop...
In the summer of 2009, a full-scale midrise wood-frame building was tested under a series of simulated earthquakes on the world’s largest shake table in Miki City, Japan. The objective of this series of tests was to validate a performance-based seismic design approach by qualitatively and quantitatively examining the building’s...
In the summer of 2009, a full-scale midrise wood-frame building was tested under a series of simulated earthquakes on the world's largest shake table in Miki City, Japan. The objective of this series of tests was to validate a performance-based seismic design approach by qualitatively and quantitatively examining the building's...
This study investigates the applicability of the database-assisted design (DAD) methodology to predict structural reactions in a light-framed wood structure subjected to fluctuating wind pressures. Structural influence functions were determined on a 1/3-scale light-frame wood structure, which was then subjected to a wind flow, while the surface pressures and structural...
Tornadoes represent a unique natural hazard because of the very low probability of occurrence, short warning times (on the order of only a few minutes), and the intense and destructive forces imposed on engineered and nonengineered buildings. The very low-probability/very high-consequence nature of a tornado strike makes designing for survival...
The effect of grain angle (GA) on shear strength of Douglas-fir has been evaluated. Shear block specimens with a GA varying from 0 to 90° was loaded in the shear plane, resulting in failure mode transitioning from parallel to grain shear to rolling shear. As expected, shear strength decreased as...
The effect of grain angle (GA) on shear strength of Douglas-fir has been evaluated. Shear block specimens with a GA varying from 0 to 90° was loaded in the shear plane, resulting in failure mode transitioning from parallel to grain shear to rolling shear. As expected, shear strength decreased as...
A numerical investigation is presented on effects of plan configuration on seismic responses of single-story, wood-frame dwellings. 151 models were developed using observations of 412 dwellings of rectangular, L, T, U, and Z-shapes in Oregon. A nonlinear, time-history program, Seismic Analysis Package for Wood-frame Structures, was the analysis platform. Models...
A numerical investigation is presented on effects of plan configuration on seismic responses of single-story, wood-frame dwellings. 151 models were developed using observations of 412 dwellings of rectangular, L, T, U, and Z-shapes in Oregon. A nonlinear, time-history program, Seismic Analysis Package for Wood-frame Structures, was the analysis platform. Models...
Goals of this preliminary study are to better understand (1) earthquake performance of wood-frame shear walls carrying gravity loads, compared with walls without gravity load, and (2) performance of walls subjected to a sequence of earthquake motions, compared with walls subjected to a single earthquake.
Tests with simulated earthquake ground...
Ten full size (3.7 x 4.9 m) plywood roof diaphragms were constructed using metal plate connected (MPC) common and hip wood trusses or joists, typical of single-family dwelling (SFD) construction. The specimens included three gable roof slopes of 33, 67 and 100%, a hip roof of 33% slope, and a...
Ten full-size (3.7×4.9m) plywood roof diaphragms were constructed using metal-plate-connected (MPC) common and hip wood trusses or joists, typical of single-family dwelling (SFD) construction. The specimens included three gable roof slopes of 33, 67, and 100%, a hip roof of 33% slope, and a flat roof, with a horizontal bottom...
Remediation methods and strength predictions were evaluated for wood I-joists with single, circular holes in the webs, leaving utilities in place. A full-scale bending test using four equally-spaced point loads was applied to three depths of joists with varying flange widths and span lengths of 4.88 m and 2.44 m....