This paper investigates a particular bridge construction technique
which could result in a significant torsional moment. The
structural member under consideration is a prestressed concrete
girder for which no torsional consideration is made.
Torsional shear stresses can be adequately approximated for
an I-shaped girder. Laboratory model tests were performed to...