A primarily software based Fourier Deep Level Transient Spectroscope (FDLTS) is built. The raw capacitance transient is acquired and digitized using capacitance meter HP4280A whereas the signal analysis is done using a customized software module. The software module calculates both the conventional DLTS spectrum and the Fourier DLTS spectrum. This...
The radiation effects in III-V heterojunction devices are investigated in this thesis. Two types of heterojunction devices studied are InGaP/GaAs single heterojunction bipolar transistors (SHBTs) and GaN-based heterojunction light emitting diodes (LEDs). InGaP/GaAS HBTs are investigated for high energy (67 and 105 MeV) proton irradiation effects while GaN heterojunction LEDs...