Metal-oxo clusters can be described as soluble pieces of metal-oxide frameworks. Currently, metal-oxo clusters are being considered as solution-based precursors for extreme ultraviolet (EUV, 13.5 nm) photoresist materials, which are a crucial component in the fabrication of microelectronic devices. Two different photoresist precursor systems have been investigated – alkyltin clusters...
A fiber optic fluorometer utilizing a double-fiber optic probe
was constructed. The absolute fluorescence signal and effective
collection efficiency are approximately one fifth those of typical
cuvette fluorometers and agree with those predicted by theory. A
quinine sulfate calibration curve shows linearity from a detection
limit of 10 pg/mL to...
The surface areas and pore size distributions of a
series of terrigenous marine sediments were measured by gas
adsorption. The sediment samples were taken from the continental
terrace off the coast of Oregon near Newport.
Sampling stations ranged up to 35 miles off shore between
44°20' and 45° north latitude....
An on-line trace enrichment (TE) system, based on high pressure
liquid chromatogroaphy (HPLC) and flame atomic absorption (AA), has
been developed for trace metal analysis. The sample is pumped through
a column filled with a cation exchange resin which traps metal ions.
The ions are subsequently stripped from the column...
Early studies on the biosynthesis of the quinoline quinone portion of
streptonigrin, 1, had suggested the intermediacy of novel aromatic amino
acids. In order to test this hypothesis, a series of compounds was synthesized
and tested for potential incorporation. [4-¹⁵N] 4-Aminoanthranilic acid,
4 5 a , [4-² H] 7-aminoquinaldinic acid,...
The relative rates of hydrogen atom abstraction from a series of 13 homoaryl
and heteroarylmethanes by the nucleophilic undecyl radical, thermally generated
from lauroyl peroxide, were determined at 70 °C. A reactivity range of 15 was
obtained. Substantial differences in reactivity among isomers were found. The
relative reactivities of the...
An automatic, continuous analyzer has been developed which
is suitable for estimating the level of spent sulfite liquors (SSL) in
laboratory samples. The analyzer makes use of a version of the
Pearl-Benson, or nitroso method, and, in its present form, is
useful for samples whose actual SSL solids concentrations are...
An analytical technique has been developed for the determination of methylmercury compounds in environmental samples. The technique is based on a two-stage procedure. In the first stage, methylmercury compounds are isolated from the sample matrix as methylmercury chloride (MeRgCl) by distillation. The distillation procedure is based on a series of...