In a homogenous and isotropic material, the location of the neutral axis coincides with the location of the centroid of the beam. Wood is anisotropic, meaning that it has different properties in different directions. It is also non-homogenous, meaning that the beam exhibits different properties at different locations throughout its...
Torsion test was evaluated as a method to determine the shear strength
parallel to grain of full-size structural composite lumber (SCL). Experimental
results of eighty-five rectangular (44 x 140 mm²) specimens were verified by finite
element analysis. Laminated strand lumber (LSL), laminated veneer lumber
(LVL) and parallel strand lumber (PSL)...
The objective of this project was to develop an analytical model of a light-framed wood structure using a prevalent structural analysis computer program in order to evaluate system effects and define load paths within the structure, especially under extreme wind events. Simplified modeling techniques and material definitions were developed and...
The overall goal of this project was to design a wood frame shear wall that could withstand greater displacement before damage occurred to the Gypsum Wall Board (GWB). More specifically, the objectives of the study were: (1) to evaluate damage to the GWB in alternative shear wall designs at 1%,...
International donors play a significant role in the mitigation and prevention of transboundary water disputes and the promotion of cooperation. In doing so, donors can exercise water diplomacy through a wide range of instruments from facilitating or mediating the negotiations to financing capacity building and specific activities in official and...
For wood beams, it is often assumed that the neutral axis is located at the centroid of the
beam. The neutral axis of isotropic, homogeneous materials is located at the centroid of the
material, but wood is neither isotropic nor homogeneous. The varying grain patterns and
knots located throughout wood...
The objective of this study was to develop and validate practical modeling
methods for investigating load paths and system behavior in a realistic, light-frame wood
structure. The modeling methods were validated against full-scale tests on subassemblies
and an L-shaped house. The model of the L-shaped house was then modified
and...
The objective of this study was to investigate load paths in an existing light-frame wood structure with complex geometry, using previously established computer modeling methods. The structural model is derived from an existing, multi-level residence located in Corvallis, Oregon. For the purpose of this study, the existing structure was simplified...
The objectives of this study are to use SAP2000 to investigate lateral load paths and system behavior in a modular, light-frame wood structure by investigating different foundation configurations and to further develop and validate existing modeling techniques of shear wall elements based on the Perforated Shear Wall Method. The modeling...
The goal of this project is to contribute to the development of design values for cross-laminated timber (CLT) diaphragms in the seismic load-resisting system for buildings. Monotonic and cyclic tests to determine strength and stiffness characteristics of 2.44 m (8 ft) long shear connections with common self-tapping screws were performed....