A method for measuring chemical reaction rates in order to
distinguish between different reaction mechanisms is presented.
This method was used to study zero -, first- and second -order reactions
by analyzing the output response to a sinusoidal input of
reactant concentrations in an isothermal continuous stirred tank
reactor.
The...
Heat transfer from the inner wall of an annulus to subcooled
water in turbulent parallel flow was studied. The inner core of the
annulus consisted of wires varying from 0.0019 to 0.0197 inch in
diameter. The outer tube consisted of a 1.01 inch diameter glass
tube 24 inches long. Diameter...
Incipient boiling and burnout heat fluxes were studied for sub-cooled forced convection annular flow. Small wires varying from 0.010
to 0.020 inch in diameter were used as the inner core of the annulus
and a one inch ID glass tube 24 inches long was used as the outer tube.
This...
Nucleate boiling of water in a vertical annulus was
studied. The test section was entirely of stainless steel
construction and was formed by a length of stainless steel
tubing with a stainless steel heater rod centered in it. Two
test sections with length to diameter ratios of 18 and 33...
The fouling characteristics of a desalted crude oil were investigated in a systematic
investigation. There are two main parts in this study, the dry bulk tests (dehydrated crude
oil) and the wet bulk tests (to which desalter brine was added). Three barrels of desalted
crude oil provided by Amoco Oil...