An experimental and numerical study of absorption of ammonia vapor bubbles into a constrained thin film of ammonia-water solution is presented in the context of a potential reduction in size of a heat-actuated heat pump component. A large-aspect-ratio channel with a depth of 600 µm restricts the thickness of the...
An experimental study of absorption of ammonia into a constrained thin film of ammonia-water solution is presented. A large aspect ratio microchannel with one of its walls formed by a porous material is used to constrain the thickness of the liquid film. Experiments were performed at a pressure of 1,...