The OSU MASLWR Test facility is a scaled integral systems LOCA and proof-of-concept test facility for the Multi-Application Small Light Water Reactor design concept. A unique feature of this design is to utilize a small high pressure containment vessel to provide the safety containment function for an integral reactor pressure...
An experimental investigation has been made of the effect of
vibration on heat transfer from a cylinder in crossflow. The
cylinder used was 3/16-inch in diameter and was sinusoidally
oscillated in the vertical direction by a mechanical drive mechanism
while immersed in an open water channel. Nominal amplitude
ratios, a/d,...
The purpose of this thesis work has been the design, construction
and calibration of an instrumented surface for convective heat
transfer studies. The surface is in the form of a flat plate roughly
24 inches wide by 48 inches long. It is made up of 48 individual
cells, laminated side-by-side...
The free convective heat transfer phenomena in air between two
vertical plates 24 by 38 inches spaced 15.895 mm apart, was investigated in this experimental study. One plate was isothermal and, the
other adiabatic.
A quartz fiber anomometer was used for measuring local
velocities in the air between the vertical...
Heat transfer from a vertical flat plate in an infinite pool of
mercury was investigated. Velocity profiles were measured with a
hot-film anemometer and simultaneous temperature profiles measured
with thermocouples in this low Prandtl number liquid metal. Constant
heat flux plates at Grashof numbers of 9 x 10⁸ and 4...
Natural convection heat transfer in air between two vertical
plates 38 by 24 inches was investigated in this work with spacings
between the plates of 0.625, 1.0 and 1.75 inches. One plate was isothermal
and the other adiabatic.
To measure the point velocities in the air layer a very thin...