Incipient boiling and burnout heat fluxes were studied for sub-cooled forced convection annular flow. Small wires varying from 0.010
to 0.020 inch in diameter were used as the inner core of the annulus
and a one inch ID glass tube 24 inches long was used as the outer tube.
This...
Nucleate boiling of water in a vertical annulus was
studied. The test section was entirely of stainless steel
construction and was formed by a length of stainless steel
tubing with a stainless steel heater rod centered in it. Two
test sections with length to diameter ratios of 18 and 33...
The purpose of this research was to study the effect of capillary
tube dimensions on the apparent viscosity of an unstable dispersion
of two immiscible liquids. The study was limited to laminar
flow at a constant temperature.
The dispersions were composed of a commercial solvent,
Shellsolv 360, manufactured by the...
An analysis of the velocity and the shape of large gas bubbles
rising through tubes filled with viscous liquids is presented. Four
tubes, with diameters ranging from 0. 446 inches to 3. 97 inches, and
three liquids, with viscosities ranging from one to 200 centipoise,
were used in the study....
Heat transfer from the inner wall of an annulus to subcooled
water in turbulent parallel flow was studied. The inner core of the
annulus consisted of wires varying from 0.0019 to 0.0197 inch in
diameter. The outer tube consisted of a 1.01 inch diameter glass
tube 24 inches long. Diameter...
Various antifoulant treatment programs and the
considerations necessary for the effective use of such
programs were examined.
Two different groups of tests, with and without
iron contamination, have been carried out on the
effectiveness of several of the state-of-the-art
copolymers (PA, HEDP, AA/HPA, AA/MA, SS/MA and AA/SA) in
the inhibition...
A study of nucleate boiling of water, four alcohols and
three ethanol-water mixtures was conducted in a vertical
thermosiphon reboiler. The test section consisted of a 1/2-
inch diameter electrically heated stainless-steel rod
jacketed by a 15-inch long pyrex glass tube. Two different
inside diameters of the glass tube corresponding...
Friction factors were measured for water flowing in ducts made
up of two rods held between two flat plates. Three rod diameters of
0.50, 1.00 and 1.50 inches were used. The spacings between rods
varied from 0.0 to 0.32 inch. It was found that the concept of
hydraulic diameter was...
Momentum transfer in climbing-film flow in an annular duct was
investigated. Air and various liquids, with a wide range of viscosities
and surface tensions, were investigated. The two phases flowed co-currently
upward, the liquid climbing as a thin film on the inner wail
while the outer wall remained dry.
The...