Flat, laminar, premixed hydrocarbon-air flames were stabilized
on a porous-plate burner. In addition to temperature profiles,
concentration profiles were measured for methane, ethane, ethylene,
propane, acetylene, propylene, carbon monoxide, carbon dioxide and
oxides of nitrogen. Dead space thickness, luminous flame zone
thickness and hydrocarbon disappearance point responses were also
monitored....