The testing of nuclear fuel under reactivity-initiated accident (RIA) conditions is paramount for the better understanding of the fuel’s behavior during this transient accident events. The Transient Reactor Test (TREAT) facility is a nuclear reactor that will be capable of recreating the thermal-hydraulic and neutronic boundary conditions representative of RIA...
The HENRI system was developed to narrow the pulse width of TREAT from 89 ms to below 60 ms with the goal of improving the test reactor's ability to simulate RIAs in LWRs by rapidly injecting helium-3, a strong neutron poison, into the core. A coupled model using the CFD...