Chromium, an element of widespread use, is toxic in some
forms. Improper disposal of waste chromium products has
resulted in contamination of many sites throughout the United
States, including the United Chrome Products Superfund site
in Corvallis, Oregon. A better understanding of chromium
chemistry is needed to facilitate the remediation...
Chromium spills on soils are causing severe groundwater contamination
problems. To increase the performance of cleanup methods, the chemical behavior
of chromium in soils and its transport through soils have to be understood. The
objectives of this research were to investigate the sorption characteristics of
chromium(VI) in soil and to...
Soil column studies were performed on a chromium contaminated soil from the United
Chrome Products Superfund Site currently undergoing a pump-and-treat cleanup process. The
goal of the research was to provide insight into the feasibility of chemically changing the injection
fluid of the pump-and-treat system to enhance hexavalent chromium (Cr(VI))...
Chromium and its compounds are widely used by modern industries, resulting in large quantities of this element being discharged into the environment. To remove chromium from contaminated soils and ground water, it is necessary to predict chemical and physical processes that control the rate of reactions and transport of chromium...
A multiple stage crosscurrent packed column suitable for gas-liquid
mass transfer was constructed and operated. The absorption
column consisted of a rectangular box constructed of plexiglass and
metal. Deflection baffles were positioned at regular intervals on
opposite sides of a central packed section to divert the gas phase
into the...
At present the adsorption kinetic of ions by soil particles is considered to be a surface reaction. When the transport of solutes in soils is described using the one-dimensional flow equation, it becomes a serious problem that lateral diffusion of ions from the bulk solution towards the soil surfaces is...
A multi-stage, crosscurrent column, packed with Pall rings, was
employed for oxygen absorption from an oxygen-rich air phase by
contacting with water. Mass transfer data were collected for the
column using 6 and 12 baffles and employing a partial gas phase recycle.