Two new experimental techniques are presented which enable the
direct measurement of heat transfer coefficients in fine particle
gas fluidized beds.
The first technique uses fine electrically heated Alumel wires
to probe fluidized beds of fine particles. The wires varied in
diameter from 50.8 to 813μm while the bed material...