An analysis of shielding requirements in conjunction with current radiographic imaging practices

公开 Deposited

可下载的内容

下载PDF文件
https://ir.library.oregonstate.edu/concern/graduate_thesis_or_dissertations/v118rh54b

Descriptions

Attribute NameValues
Creator
Abstract
  • The National Council of Radiation Protection and Measurements Report No. 49, originally issued on September 15, 1976, has been the primary design guide for diagnostic x-ray structural shielding in the United States. To further protect the public from various areas of medical radiation exposure, NCRP issued Report 116 in 1987 to decrease the public exposure limits. These new limits used in conjunction with NCRP 49 to determine shielding requirements for diagnostic radiological rooms can be shown to over-shield based on current technologies and protocols. This paper explores the NCRP conservative assumptions that physicists specifying barrier requirements for diagnostic x-ray facilities normally utilize. These evaluated assumptions, which are incorporated in the methodology and attenuation data presented in NCRP Report 49 formulas, include relatively high single kVp's, a "one size fits all" workload default, and the lack of attenuation factors by the patient, the wall, and the film. In essence, an analysis of the conservative nature of NCRP 49 is demonstrated. An example of Primary and Secondary Shielding Methodology utilizing NCRP 49 and NCRP 116 dose limits is provided as well as the cost factors associated with the results. These examples are further evaluated using a Monte Carlo software program. In addition, an analysis of actual current radiographic conditions in an imaging room is performed. This is done to determine first, the actual mA utilized for specific exams; secondly, the actual mA-min weekly workload; and thirdly, the tangible exams performed per week in small and large medical facilities. Based on the information and analysis presented, this paper concludes that the formulas for NCRP 49 and NCRP 116 need to be reexamined. Furthermore, this paper also demonstrates once again that NCRP 49, utilizing NCRP 116 dose limits is extremely conservative.
Resource Type
Date Available
Date Issued
Degree Level
Degree Name
Degree Field
Degree Grantor
Commencement Year
Advisor
Academic Affiliation
Non-Academic Affiliation
Subject
权利声明
Publisher
Peer Reviewed
Language
Digitization Specifications
  • File scanned at 300 ppi (Monochrome, 256 Grayscale) using Capture Perfect 3.0.82 on a Canon DR-9080C in PDF format. CVista PdfCompressor 4.0 was used for pdf compression and textual OCR.
Replaces

关联

Parents:

This work has no parents.

属于 Collection:

单件