The theory and ways of applying a new electroanalytical detectior
method were developed. The method, called galvanovoltammetry,
consists of the measurement of current from the bipolar electrode of
a three electrode cell which consists of a working electrode and a
counter electrode, between which a constant current is applied, and...
As with many pairs of metals, the electrodeposition of Pb-Tl, Cu-Cd, and Cu-Ni at solid electrodes yielded partial polarization curves shifted from the polarization curves of the single metals. The curves for the more noble metals (Pb, Cu) were shifted negatively while the less noble metals'(Tl, Cd, Ni) curves were...
Optimization of the galvanovoltammetric determination of dissolved
chlorine in a flowing stream was achieved through the use of
an analog computational device and improvements in the design of the
galvanovoltammetric cell and accompanying electronic circuitry. An
analysis system, applicable to industrial use over a range of flow
rates and dissolved...